Hb F is eluted from the column resin by a programmed buffer gradient of increasing ionic strength.
Hb F level is useful for following hydroxyurea therapy for sickle cell patients.
Hb F measurement is best interpreted in conjunction with other testing in the Thalassemia Reflexive Panel, red cell indices, patient demographics and other clinical factors.
High Performance Liquid Chromatography (HPLC)
Female | Male | ||
---|---|---|---|
Age | Range | Age | Range |
0-4m | 5-90 | 0-4m | 5-90 |
5m | 5-20 | 5m | 5-20 |
6m-8m | <8 | 6m-8m | <8 |
9m | <5 | 9m | <5 |
10m-3y | <3 | 10m-3y | <3 |
4y-10y | <2 | 4y-10y | <2 |
11y- | <1.1 | 11y- | <1.1 |
Effective date: 09/19/2005
3 mL LAVENDER TOP tube
Pediatric draw: (3) LAVENDER TOP MICROTAINERS
Refrigerate whole blood Stability: EDTA: Refrigerated, 7 days. Ambient, 2 days.
Unacceptable: Other anticoagulants, Frozen specimens.
HMC |
Red Cell Disorders
206-520-4600 325 9th Ave, Rm # GWH-47, Seattle, WA 98104-2420 |
---|