ColoSeq - Lynch and Polyposis Panel

tabbed view

General Information

Lab Name
ColoSeq: Lynch and Polyposis
Lab Code
COSEQ
Epic Ordering
ColoSeq - Lynch And Polyposis
Description

ColoSeq™ is a comprehensive genetic test for hereditary colon cancer that uses next-generation sequencing to detect most variants in APC*, AXIN2, BMPR1A, CDH1, CHEK2, CTNNA1, EPCAM, GREM1, MLH1*, MLH3, MSH2*, MSH3, MSH6*, MUTYH, NTHL1, PDGFRA, PIK3CA, PMS2*, POLD1, POLE, PTEN, RNF43, RPS20, SMAD4, STK11, and TP53. Mutations in these genes are associated with Lynch syndrome (MLH1, MSH2, MSH6, PMS2, EPCAM), familial adenomatous polyposis (APC), MUTYH-associated polyposis, Li- Fraumeni (TP53), Hereditary Diffuse Gastric Cancer (CDH1), Cowden syndrome (PTEN), Peutz-Jeghers syndrome (STK11), Turcot syndrome (APC), PTEN Hamartoma Tumor syndrome (PHTS), Bannayan-Riley-Ruvalcaba syndrome (PTEN), and Juvenile Polyposis syndrome (SMAD4 and BMPR1A). The assay completely sequences all exons, flanking regions of these genes and detects large deletions and duplications. For genes indicated above with *, intronic regions are sequenced. The panel capture detects the MSH2 exon 1-7 inversion (since 2015) described by Rhees, Arnold and Boland 2014. The panel also includes promoter 1B regions of the APC gene including deletions and gastric polyposis causing variants reported in Li et al. 2016.

ColoSeq™ Tumor

Beginning in 2014, ColoSeq™ Tumor is offered for the detection of somatic mutations in tumors. Double somatic mismatch repair (MMR) mutations have been reported in colon and endometrial cancers which have IHC loss of MMR protein(s) and normal (negative) germline MMR testing (Mensenkamp et al. 2014, Haraldsdottir et al. 2014). In the absence of a germline MMR mutation, the presence of double somatic mutations in tumor greatly reduces the likelihood that IHC loss of MMR protein(s) is due to an undetected germline mutation, reducing the likelihood the patient has Lynch syndrome.

ColoSeq™ Tumor is an option for patients who have had abnormal MMR IHC and normal germline testing, such as ColoSeq™. ColoSeq™ Tumor can also assess microsatellite instability in colon cancer (Salipante 2014) and BRAF V600E status. ColoSeq™ Tumor Single Gene and ColoSeq™ Tumor Panel testing are available. See ColoSeq Tumor Panel [CSQTP] for additional information.

NOTE: If germline MMR testing was performed in a different laboratory, a peripheral blood sample should be submitted in addition to the tumor tissue.

ColoSeq™ Panel Genes

Gene RefSeq Disease Association or Cancer Risk Complete Sequencing Del/Dup Added
APC
NM_000038.5
FAP, Turcot Yes Yes November 2011
AXIN2 NM_004655.3

Colon cancer, oligodontia Yes Yes February 2015
BMPR1A NM_004329.2 Juvenile Polyposis Yes Yes January 2013
CDH1 NM_004360.3 Hereditary diffuse gastric cancer Yes Yes June 2012
CHEK2 NM_007194.3 Li-Fraumeni-like Yes Yes February 2015

CTNNA1

NM_0011903.2 Hereditary diffuse gastric cancer Yes Yes October 2014
EPCAM NM_002354.2 Lynch Yes Yes November 2011
GREM1 NM_001191323.1 Polyposis Yes Yes October 2013
MLH1 NM_000249.3 Lynch, Muir-Torre Yes Yes November 2011
MLH3 NM_001040108.1 Mismatch repair deficiency Yes Yes June 2020

MSH2,includes
exon1-7inversion

NM_000251.1 Lynch, Muir-Torre Yes Yes November 2011
MSH3 NM_002439.4 Colon polyposis (recessive) Yes Yes January 2017
MSH6 NM_000179.2 Lynch Yes Yes November 2011
MUTYH NM_001128425.1 MUTYH-associated polyposis Yes Yes November 2011
NTHL1 NM_002528.5 Colon polyposis (recessive) Yes Yes July 2016
PDGFRA

NM_006206

GIST Yes Yes July 2016
PIK3CA NM_006218.2 Cowden-like, Breast, thyroid cancer, macrocephaly Yes Yes October 2013
PMS2 NM_004655.3 Lynch Yes Yes November 2011
POLD1 NM_002691.3 Colon cancer Yes Yes October 2013
POLE NM_006231.2 Colon cancer Yes Yes October 2013
PTEN NM_000314.4 Cowden Yes Yes June 2012
RNF43 NM_017763 Serrated polyposis Yes Yes June 2020
RPS20 NM_001023.3 Colon cancer Yes Yes February 2015
SMAD4 NM_005359.5 Juvenile Polyposis Yes Yes January 2013
STK11 NM_000455.4 Peutz-Jeghers Yes Yes June 2012
TP53 NM_000546.5 Li-Fraumeni Yes Yes June 2012

Single Gene Testing Available for any Gene on ColoSeq™

For information on single gene testing see BROCA/ColoSeq™ - Single Gene Analysis [SGN]

Known Mutation Testing

Known mutation testing is available for mutations identified at UW Laboratory Medicine. For information on single site testing of a known mutation in one of the genes listed above see BROCA/ColoSeq™ - Known Mutation Testing [KMU].

For previous versions of ColoSeq™ - Lynch and Polyposis Panel, see Previous Versions, COSEQ.

References
  • Pritchard CC, et al. ColoSeq provides comprehensive lynch and polyposis syndrome mutational analysis using massively parallel sequencing. J Mol Diagn 2012, 14:357-66. 22658618
  • Walsh T, et al. Detection of inherited mutations for breast and ovarian cancer using genomic capture and massively parallel sequencing. Proc Natl Acad Sci U S A 2010, 107:12629-33. 20616022
  • Nord AS, Lee M, King MC, and Walsh T. Accurate and exact CNV identification from targeted high-throughput sequence data. BMC Genomics 2011, 12:184. 21486468
  • Metzker ML. Sequencing technologies - the next generation. Nat Rev Genet 2010, 11:31-46. 19997069
  • Rhees J, Arnold M, and Boland CR. Inversion of exons 1-7 of the MSH2 gene is a frequent cause of unexplained Lynch syndrome in one local population. Fam Cancer 2014, 13:219-25. 24114314
  • Li J et al. Point Mutations in Exon 1B of APC Reveal Gastric Adenocarcinoma and Proximal Polyposis of the Stomach as a Familial Adenomatous Polyposis Variant. Am J Hum Genet 2016 May, 5;98(5):830-842. 27087319
  • Mensenkamp AR, et al. Somatic mutations in MLH1 and MSH2 are a frequent cause of mismatch-repair deficiency in Lynch syndrome-like tumors. Gastroenterology 2014, 146:643-646.e8. 24333619
  • Haraldsdottir S, et al. Colon and endometrial cancers with mismatch repair deficiency can arise from somatic, rather than germline, mutations. Gastroenterology 2014, 147:1308-1316.e1. 25194673
  • Salipante SJ, Scroggins SM, Hampel HL, Turner EH, and Pritchard CC. Microsatellite instability detection by next generation sequencing. Clin Chem 2014, 60:1192-9. 24987110
  • Herman DS, et al. Efficient Detection of Copy Number Mutations in PMS2 Exons with a Close Homolog. J Mol Diagn 2018, 20:512-521. 29792936

For providers interested in more information on interpreting genetic test results for your patient, please see the Guide to Interpreting Genomic Reports: A Genomics Toolkit

Synonyms
Adenomatous polyposis, APC, AXIN2, BMPR1A, CDH1, CHEK2, Colon cancer, ColoSeq Tumor, Cowden, CSQTP, CSQTS, CTNNA1, EPCAM, FAP, GREM1, HDGC, Hereditary nonpolyposis colorectal cancer, HNPCC, Juvenile Polyposis, Li-Fraumeni, Lynch Syndrome, MLH1, MLH3, MSH2, MSH3, MSH6, MSI, MUTYH, Next-generation sequencing, NTHL1, PDGFRA, Peutz-Jeghers, PIK3CA, PMS2, POLD1, POLE, PTEN, RNF43, RPS20, SMAD4, STK11, TP53
Components

Interpretation

Method

Next-generation sequencing.

This assay sequences all exons, and select promoter regions of APC*, AXIN2, BMPR1A, CDH1, CTNNA1, EPCAM, GREM1, MLH1*, MLH3, MSH2*, MSH3, MSH6*, MUTYH, NTHL1, PDGFRA, PIK3CA, PMS2*, POLE, POLD1, PTEN, RNF43, RPS20, SMAD4, STK11, and TP53. For genes marked with *, intronic regions are also sequenced. Sequences are aligned to the human genome reference (hg19). Test performed by targeted capture for listed genes followed by next-generation sequencing with Illumina technology. This test was developed and its performance characteristics determined by the University of Washington Department of Laboratory Medicine. It has not been cleared or approved by the US Food and Drug Administration. This laboratory is certified under the Clinical Laboratory Improvement Amendments (CLIA) as qualified to perform high complexity clinical laboratory testing. This test is used for clinical purposes. It should not be regarded as investigational or for research.

Reference Range
See individual components
Ref. Range Notes

No mutations detected.

Guidelines

Ordering & Collection

Specimen Type
Peripheral Blood or purified DNA from peripheral blood. Saliva: Contact laboratory for validated collection kit. For other sample types such as tumor, fresh tissue or cultured cells, please order ColoSeq™ Tumor Panel.
Collection

ColoSeq™:

BLOOD:

  • 10 mL whole blood in LAVENDER TOP EDTA tube.
  • Also acceptable: YELLOW TOP ACD tube, purified DNA from peripheral blood.

SALIVA: Contact laboratory for validated collection kit.

Forms & Requisitions

Complete UW-MT Genetics Requisition.

For ColoSeq™:

  • In “Next Generation Sequencing" section of test requisition, check: "ColoSeq™ – Lynch and Polyposis Panel"
Handling Instructions

Ship specimen at room temperature for overnight delivery.

Blood specimens can be held for up to 7 days before shipping if refrigerated.

Ship specimens to:

UW MEDICAL CENTER

LABORATORY MEDICINE - GENETICS LAB

1959 NE PACIFIC ST, ROOM NW220

SEATTLE, WA 98195-7110

Quantity
requested: entire sample
minimum: 5 mL whole blood

Processing

Processing

Blood: Refrigerate whole blood

Unacceptable Conditions: Frozen or clotted specimens

Stability (collection to initiation of testing): Ambient: 5 days; Refrigerated: 7 days; Frozen: Unacceptable

Purified DNA: Refrigerate DNA specimens. Frozen is acceptable.

Performance

LIS Dept Code
Genetics (GEN)
Performing Location(s)
UW-MT Genetics

Attention: Genetics Lab
Clinical lab, Room NW220
University of Washington Medical Center
1959 NE Pacific Street
Seattle, WA 98195

Tel: 206-598–6429 M–F (7:30 AM–4:00 PM)
Fax: 206-616-4584
Lab email: cgateam@uw.edu

Tel (EXOME only): 206-543-0459

Faculty
Jillian Buchan, PhD, FACMG
Runjun Kumar, MD, PhD
Regina Kwon, MD, MPH
Christina Lockwood, PhD, DABCC, DABMGG
Abbye McEwen, MD, PhD
Colin Pritchard, MD, PhD
Vera Paulson, MD, PhD
Eric Konnick, MD, MS
He Fang, PhD

Frequency
Results within 2-3 weeks, once all samples arrive in the laboratory.
Available STAT?
No

Billing & Coding

CPT codes
Billing Comments

For additional test/billing information, see following page: ColoSeq™ – Lynch and Polyposis CPT codes or ColoSeq™ Tumor CPT codes.

For pricing information, contact Client Support Services 206-520-4600 or 800-713-5198.

Billing and Insurance Pre-Authorization

We offer insurance pre-authorization services (preauthorization is only done for providers who are external to the UW system).

Email: gpab@uw.edu or call 1-855-320-4869 for more information.

A letter of medical necessity is highly recommended for ColoSeq™ Tumor testing, and a template is available by emailing genelab@uw.edu.

Genetics Preauthorization Form

LOINC
41103-3
Interfaced Order Code
UOW2452